ChasteGuides/ChasteUnits

Units

Cardiac Chaste Units

Note: F=Farad, S=Siemen=Amp/Volt, A=Ampere, u=micro (ie mu).

Quantity Units Notes
Length cm hence surface-area-to-volume ratio is cm-1 etc
Time ms
Voltage or intra- or extracellular potential mV
Capacitance per unit surface area uF cm-2 Cm, which we refer to as the capacitance, is actually a capacitance per unit area. The SI unit
of capicitance is the Farad ( = Coulombs/Volts) (C=Q/V)
Conductivities mS cm-1
(Stimulus) currents per unit volume uA cm-3 Applies to (intracellular) stimulus currents given to cells in mono/bidomain problems
(ie a stimulus current as a RHS source term in the bidomain equations. Note we don't allow
RHS extracellular stimuli)
Currents per unit area uA cm-2 Applies to all ionic currents (single-cell/mono/bidomain equations), intracellular stimuli
in single-cell problems or applied as Neumann boundary conditions, and extracellular
stimuli through electrodes (which are also Neumann boundary conditions)

Cancer Chaste Units

Quantity Units Notes
Length dimensionless Nondimensionalised by typical cell diameter (approx 10-5 m)
Time hours